{"id":4983,"date":"2024-03-12T14:16:48","date_gmt":"2024-03-12T06:16:48","guid":{"rendered":"https:\/\/www.sevencrane.com\/?p=4983"},"modified":"2024-03-12T14:18:04","modified_gmt":"2024-03-12T06:18:04","slug":"common-electrical-faults-of-garbage-grab-bridge-crane","status":"publish","type":"post","link":"https:\/\/www.sevencrane.com\/bs\/common-electrical-faults-of-garbage-grab-bridge-crane\/","title":{"rendered":"Uobi\u010dajeni elektri\u010dni kvarovi mostne dizalice za sme\u0107e"},"content":{"rendered":"<p>Kran za grabljenje sme\u0107a je jedna od va\u017enih opreme u elektranama za spaljivanje sme\u0107a. Njegova funkcija je hvatanje, mije\u0161anje i zonsko fermentiranje ku\u0107nog otpada u jami za skladi\u0161tenje ku\u0107nog otpada. I stavite fermentirani ku\u0107ni otpad u kotao za spaljivanje za spaljivanje. Razumijevanje elektri\u010dne opreme dizalica za otpatke je od velike pomo\u0107i za normalan rad postrojenja za spaljivanje ku\u0107nog otpada. Istovremeno je koristan i za kori\u0161tenje i odr\u017eavanje dizalica za otpatke u svakodnevnom \u017eivotu.<\/p>\n\n\n\n<p>1. Ograni\u010dite kvar sistema<\/p>\n\n\n\n<p>Glavna funkcija grani\u010dnog prekida\u010da je da ograni\u010di radni opseg mostne dizalice za otpatke. I osigurajte da oprema normalno radi u sigurnom podru\u010dju. Kada se grani\u010dni prekida\u010d mehanizma za prevo\u0111enje sudari sa ravnalom, grani\u010dni prekida\u010d se aktivira, a PLC \u0107e zaustaviti rad mehanizma nakon \u0161to primi signal. Glavni simptomi kvarova grani\u010dnih prekida\u010da uklju\u010duju:<\/p>\n\n\n\n<p>1) Grani\u010dni prekida\u010d translatornog mehanizma<\/p>\n\n\n\n<p>Dizalica ne mo\u017ee raditi jer nije stigla do podru\u010dja zaustavljanja, ali je krajnji prekida\u010d aktiviran. Ili do\u0107i do podru\u010dja zaustavljanja, ali se grani\u010dni prekida\u010d ne aktivira, \u0161to uzrokuje da dizalica prekora\u010di radnu zonu.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/d3fnmw4lwrx8lm.cloudfront.net\/wp-content\/uploads\/2019\/04\/08151612\/12.5T-grab-crane.jpg\" alt=\"12.5T grabilica\" class=\"wp-image-3108 lazyload\"\/><noscript><img decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/d3fnmw4lwrx8lm.cloudfront.net\/wp-content\/uploads\/2019\/04\/08151612\/12.5T-grab-crane.jpg\" alt=\"12.5T grabilica\" class=\"wp-image-3108 lazyload\" srcset=\"https:\/\/d3fnmw4lwrx8lm.cloudfront.net\/wp-content\/uploads\/2019\/04\/08151612\/12.5T-grab-crane.jpg 800w, https:\/\/d3fnmw4lwrx8lm.cloudfront.net\/wp-content\/uploads\/2019\/04\/08151612\/12.5T-grab-crane-300x225.jpg 300w, https:\/\/d3fnmw4lwrx8lm.cloudfront.net\/wp-content\/uploads\/2019\/04\/08151612\/12.5T-grab-crane-768x576.jpg 768w, https:\/\/d3fnmw4lwrx8lm.cloudfront.net\/wp-content\/uploads\/2019\/04\/08151612\/12.5T-grab-crane-428x321.jpg 428w, https:\/\/d3fnmw4lwrx8lm.cloudfront.net\/wp-content\/uploads\/2019\/04\/08151612\/12.5T-grab-crane-345x258.jpg 345w, https:\/\/d3fnmw4lwrx8lm.cloudfront.net\/wp-content\/uploads\/2019\/04\/08151612\/12.5T-grab-crane-253x190.jpg 253w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/noscript><\/figure>\n\n\n\n<p>2. Grani\u010dni prekida\u010d visine mehanizma za podizanje<\/p>\n\n\n\n<p>Glavni kvar koji se dogodio je aktiviran na pogre\u0161noj visini, zbog \u010dega mehanizam za podizanje nije dosegao potrebnu visinu za rad. Ili se za\u0161tita ograni\u010denja visine ne aktivira na normalnoj visini.<\/p>\n\n\n\n<p>2. Neispravnost sistema kodera<\/p>\n\n\n\n<p>1) Odstupanje izme\u0111u prikazanog putovanja na ekranu osjetljivom na dodir i stvarnog putovanja je zna\u010dajno.<\/p>\n\n\n\n<p>2) Hod na ekranu osetljivom na dodir ostaje nepromenjen ili su podaci abnormalni, a PLC prikazuje gre\u0161ku u modulu enkodera.<\/p>\n\n\n\n<p>3. Neispravnost sistema za vaganje<\/p>\n\n\n\n<p>1) Postoji odstupanje u kvalitetu koji prikazuje vaga.<\/p>\n\n\n\n<p>2) Postoji problem sa zapisom napajanja industrijskog ra\u010dunara.<\/p>\n\n\n\n<p>Zbog posebnog radnog okru\u017eenja i radnih karakteristika mosne dizalice za otpatke, svakodnevni pregled i odr\u017eavanje opreme su tako\u0111e veoma va\u017eni. Rano otkrivanje abnormalnih elektri\u010dnih komponenti i odr\u017eavanje ili zamjena su od su\u0161tinskog zna\u010daja za su\u0161tinsko smanjenje vjerojatnosti elektri\u010dnih kvarova u dizalicama za otpatke.<\/p>","protected":false},"excerpt":{"rendered":"<p>Kran za grabljenje sme\u0107a je jedna od va\u017enih opreme u elektranama za spaljivanje sme\u0107a. Njegova funkcija je hvatanje, mije\u0161anje i zonsko fermentiranje ku\u0107nog otpada u jami za skladi\u0161tenje ku\u0107nog otpada. I stavite fermentirani ku\u0107ni otpad u kotao za spaljivanje za spaljivanje. Razumijevanje elektri\u010dne opreme dizalica za otpatke je od...<\/p>","protected":false},"author":2,"featured_media":3108,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3],"tags":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v21.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Common Electrical Faults of Garbage Grab Bridge Crane<\/title>\n<meta name=\"description\" content=\"Understanding the garbage grab bridge crane is of great help for the normal operation of household waste incineration plants.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sevencrane.com\/bs\/common-electrical-faults-of-garbage-grab-bridge-crane\/\" \/>\n<meta property=\"og:locale\" content=\"bs_BA\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Common Electrical Faults of Garbage Grab Bridge Crane\" \/>\n<meta property=\"og:description\" content=\"Understanding the garbage grab bridge crane is of great help for the normal operation of household waste incineration plants.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sevencrane.com\/bs\/common-electrical-faults-of-garbage-grab-bridge-crane\/\" \/>\n<meta property=\"og:site_name\" content=\"SEVENCRANE\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/sevencrane.china\" \/>\n<meta property=\"article:published_time\" content=\"2024-03-12T06:16:48+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-03-12T06:18:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/d3fnmw4lwrx8lm.cloudfront.net\/wp-content\/uploads\/2019\/04\/08151612\/12.5T-grab-crane.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"sevencrane\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"sevencrane\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sevencrane.com\/common-electrical-faults-of-garbage-grab-bridge-crane\/\",\"url\":\"https:\/\/www.sevencrane.com\/common-electrical-faults-of-garbage-grab-bridge-crane\/\",\"name\":\"Common Electrical Faults of Garbage Grab Bridge Crane\",\"isPartOf\":{\"@id\":\"https:\/\/www.sevencrane.com\/#website\"},\"datePublished\":\"2024-03-12T06:16:48+00:00\",\"dateModified\":\"2024-03-12T06:18:04+00:00\",\"author\":{\"@id\":\"https:\/\/www.sevencrane.com\/#\/schema\/person\/7545811fa32bdea266b99e117e109ee3\"},\"description\":\"Understanding the garbage grab bridge crane is of great help for the normal operation of household waste incineration plants.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sevencrane.com\/common-electrical-faults-of-garbage-grab-bridge-crane\/#breadcrumb\"},\"inLanguage\":\"bs-BA\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sevencrane.com\/common-electrical-faults-of-garbage-grab-bridge-crane\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sevencrane.com\/common-electrical-faults-of-garbage-grab-bridge-crane\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sevencrane.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\/\/www.sevencrane.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Common Electrical Faults Of Garbage Grab Bridge Crane\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sevencrane.com\/#website\",\"url\":\"https:\/\/www.sevencrane.com\/\",\"name\":\"SEVENCRANE\",\"description\":\"overhead crane\/gantry crane\/jib crane\/electric hoist\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sevencrane.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"bs-BA\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.sevencrane.com\/#\/schema\/person\/7545811fa32bdea266b99e117e109ee3\",\"name\":\"sevencrane\",\"sameAs\":[\"sevencrane\"],\"url\":\"https:\/\/www.sevencrane.com\/bs\/author\/sevencrane\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Common Electrical Faults of Garbage Grab Bridge Crane","description":"Understanding the garbage grab bridge crane is of great help for the normal operation of household waste incineration plants.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sevencrane.com\/bs\/common-electrical-faults-of-garbage-grab-bridge-crane\/","og_locale":"bs_BA","og_type":"article","og_title":"Common Electrical Faults of Garbage Grab Bridge Crane","og_description":"Understanding the garbage grab bridge crane is of great help for the normal operation of household waste incineration plants.","og_url":"https:\/\/www.sevencrane.com\/bs\/common-electrical-faults-of-garbage-grab-bridge-crane\/","og_site_name":"SEVENCRANE","article_publisher":"https:\/\/www.facebook.com\/sevencrane.china","article_published_time":"2024-03-12T06:16:48+00:00","article_modified_time":"2024-03-12T06:18:04+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/d3fnmw4lwrx8lm.cloudfront.net\/wp-content\/uploads\/2019\/04\/08151612\/12.5T-grab-crane.jpg","type":"image\/jpeg"}],"author":"sevencrane","twitter_card":"summary_large_image","twitter_misc":{"Written by":"sevencrane","Est. reading time":"3 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sevencrane.com\/common-electrical-faults-of-garbage-grab-bridge-crane\/","url":"https:\/\/www.sevencrane.com\/common-electrical-faults-of-garbage-grab-bridge-crane\/","name":"Common Electrical Faults of Garbage Grab Bridge Crane","isPartOf":{"@id":"https:\/\/www.sevencrane.com\/#website"},"datePublished":"2024-03-12T06:16:48+00:00","dateModified":"2024-03-12T06:18:04+00:00","author":{"@id":"https:\/\/www.sevencrane.com\/#\/schema\/person\/7545811fa32bdea266b99e117e109ee3"},"description":"Understanding the garbage grab bridge crane is of great help for the normal operation of household waste incineration plants.","breadcrumb":{"@id":"https:\/\/www.sevencrane.com\/common-electrical-faults-of-garbage-grab-bridge-crane\/#breadcrumb"},"inLanguage":"bs-BA","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sevencrane.com\/common-electrical-faults-of-garbage-grab-bridge-crane\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.sevencrane.com\/common-electrical-faults-of-garbage-grab-bridge-crane\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sevencrane.com\/"},{"@type":"ListItem","position":2,"name":"Blog","item":"https:\/\/www.sevencrane.com\/blog\/"},{"@type":"ListItem","position":3,"name":"Common Electrical Faults Of Garbage Grab Bridge Crane"}]},{"@type":"WebSite","@id":"https:\/\/www.sevencrane.com\/#website","url":"https:\/\/www.sevencrane.com\/","name":"SEVENCRANE","description":"overhead crane\/gantry crane\/jib crane\/electric hoist","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sevencrane.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"bs-BA"},{"@type":"Person","@id":"https:\/\/www.sevencrane.com\/#\/schema\/person\/7545811fa32bdea266b99e117e109ee3","name":"sevencrane","sameAs":["sevencrane"],"url":"https:\/\/www.sevencrane.com\/bs\/author\/sevencrane\/"}]}},"_links":{"self":[{"href":"https:\/\/www.sevencrane.com\/bs\/wp-json\/wp\/v2\/posts\/4983"}],"collection":[{"href":"https:\/\/www.sevencrane.com\/bs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sevencrane.com\/bs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sevencrane.com\/bs\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sevencrane.com\/bs\/wp-json\/wp\/v2\/comments?post=4983"}],"version-history":[{"count":1,"href":"https:\/\/www.sevencrane.com\/bs\/wp-json\/wp\/v2\/posts\/4983\/revisions"}],"predecessor-version":[{"id":4984,"href":"https:\/\/www.sevencrane.com\/bs\/wp-json\/wp\/v2\/posts\/4983\/revisions\/4984"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sevencrane.com\/bs\/wp-json\/wp\/v2\/media\/3108"}],"wp:attachment":[{"href":"https:\/\/www.sevencrane.com\/bs\/wp-json\/wp\/v2\/media?parent=4983"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sevencrane.com\/bs\/wp-json\/wp\/v2\/categories?post=4983"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sevencrane.com\/bs\/wp-json\/wp\/v2\/tags?post=4983"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}